A variety of extruded 1, 2, 3, 4, 5, 6 and 7 inch louvers for mechanical and architectural applications. AMCA and NOA certified architectural louvers available. Air Performance can accommodate special requests and new extrusions needs for custom job specifications and requirements.

2 Inch Louvers

2DB45

2" Drainable Blade Stationary Louver

Frame: 2" deep, 6063-T5 extruded aluminum .063" nominal wall thickness. Blades: 6063-T5 extruded aluminum. .063" nominal wall thickness. Blades are positioned at a 45° angle.

Aluminum construction providing high resistance to corrosion. 54% Free Area.(Based on 48" x 48" Unit) Drainable head collects and channels water to drainable jamb to provide excellent water penetration performance. Drainable blade channels water to drainable jamb minimizing water cascade between the blades. Hidden mullions allow for continuous blade appearance up to 120".

Submittal / Tech Data

2HP45

2" Drainable Stationary Louver

Aluminum construction providing high resistance to corrosion. 58% Free Area.(Based on 48" x 48" Unit) Drainable head collects and channels water to drainable jamb to provide excellent water penetration performance. Hidden mullions allow for continuous blade appearance up to 120"

Submittal / Tech Data

APD2

High Performance 2" Fixed Louver

Frame: .060 Extruded Aluminum, 2/16" Deep. Glad: .060 Extruded Aluminum positioned on a 37° angle on approximately 1/47" centers.

Submittal / Tech Data

APEL2

High Performance 2" Fixed Louver

Frame: .060 (1.52 mm) Extruded Aluminum, 2/16" (55 mm) Deep. Blade: .060 (1.52 mm) Extruded Aluminum positioned on a 37° angle on approximately 1/47" (37 mm) centers.

Submittal / Tech Data
Wind Driven Rain

APXS2

High Performance 2" Fixed Louver

Frame: .060 Extruded Aluminum, 2/16" Deep. Blade: .060 Extruded Aluminum on approximately 0.938" centers.

Submittal / Tech Data

3 Inch Louvers

AMCA 540/550 Rated

WDV-75

3" Deep Vertical Blade Wind-Driven Rain/Hurricane Louver

Frame: .081 Extruded Aluminum 3" (76.2mm) Deep

Blades: .10" (2.54mm) Extruded Aluminum on 13/16" (20.638) Centers

4 Inch Louvers

4D375

4" Drainable Stationary Louver

Frame: 4" deep, 6063-T5 extruded aluminum. .081" nominal wall thickness. Blades: 6063-T5 extruded aluminum. .081" nominal wall thickness. Blades are positioned at a 37.5° angle and spaced on approximately 5.062" centers.

Submittal / Tech Data

4DB4

4" Drainable Stationary Louver

Frame: 4" deep, 6063-T5 extruded aluminum. .081" nominal wall thickness. Blades: 6063-T5 extruded aluminum. .081" nominal wall thickness. Blades are positioned at a 45 degree blade angle and spaced on approximately 4" centers.

Submittal / Tech Data

4Z375

4" Stationary Louver

Frame: 4" deep, 6063-T5 extruded aluminum. .081" nominal wall thickness. Blades: 6063-T5 extruded aluminum. .081" nominal wall thickness. Blades are positioned at a 37.5° angle and spaced on approximately 5.062" centers.

Submittal / Tech Data

4ZB4

4" Stationary J Blade Louver

Frame: 4" deep, 6063-T5 extruded aluminum. .081" nominal wall thickness. Blades: 6063-T5 extruded aluminum. .081" nominal wall thickness. Blades are positioned at a 45 degree blade angle and spaced on approximately 4" centers.

Submittal / Tech Data

APD4

High Performance 4" Fixed Louver

Frame: .81 Extruded Aluminum, 4.19" Deep. Blade: .081 Extruded Aluminum positioned on a 45° angle on approximately 2.88" centers.

Submittal / Tech Data

APEL4

High Performance 4" Fixed Louver

Frame: .081 Extruded Aluminum, 4.16" Deep. Blade: .081 Extruded Aluminum positioned on a 40° angle on approximately 4.625" centers.

Submittal / Tech Data

APHFA4

.081 Frame and .060 blade thickness, with 3.75 drainable blade spacing. 50 degree blade angle
Submittal / Tech Data

APHV4

Frame: .081 Extruded Aluminum, 4.16" (105 mm) Deep. Horizontal (front) Blade: .060 Extruded Aluminum on approximately 1/5" (37 mm) centers. Vertical (rear) Blade: .060 Extruded Aluminum on approximately .75" (19 mm) centers. Class A
Submittal / Tech Data
Miami Dade County Hurricane Rated

DCFL-D-4

High Performance 4" Hurricane Louver

The Model DCFL-D-4 is a. lover designed to protect the outside opening in building exterior walls. It is engineered for use in Dade County and its municipalities as well as other regions that use Dade County codes.

Submittal / Tech Data

5 Inch Louvers

Miami Dade County Approved

5WDRL-CF (Miami-Dade)

5" Miami-Dade Approved Wind Driven Rain Resistant Louver W/Channel Frame

Frame: 5" deep, 6063-T5 extruded aluminum. .081" nominal wall thickness. Blades: 6063-T5 extruded aluminum .081" nominal wall thickness. Double Drainable , sight-proof blades spaced on approximately 2.125" centers.

Submittal / Tech Data
Wind Driven Rain

5WDRL-HP

5" Stationary Wind Driven Rain Resistant Louver W/Channel Frame

Frame: 5" deep, 6063-T5 extruded aluminum .081" nominal wall thickness. Blades: 6063-T5 extruded aluminum .081" nominal wall thickness. Double Drainable , sight-proof blades spaced on approximately 2" centers.

Submittal / Tech Data
Wind Driven Rain

5WDRL-V

5" Stationary Wind Driven Rain Resistant Louver

Frame: 5" deep, 6063-T5 extruded aluminum. .081" nominal wall thickness. Blades: 6063-T5 extruded aluminum. .065" nominal wall thickness. Double Drainable , sight-proof blades spaced on approximately 2" centers.

Submittal / Tech Data
AMCA 540/550 Rated

WDV-130

5" Deep Vertical Blade Wind Driven Rain/Hurricane Louver

Frame: .081 Extruded Aluminum, 5.1" (130 mm) Deep. Blades: .063" (1.6 mm) Extruded Aluminum on approximately 1.50" (38 mm) centers.

Submittal / Tech Data

6 Inch Louvers

6D375

6" Drainable Stationary Louver W/ Channel Frame (.081 Blades)

Frame: 6" deep, 6063-T5 extruded aluminum. .125" nominal wall thickness. Blades: 6063-T5 extruded aluminum. .081" nominal wall thickness. Blades are positioned at a 37.5° angle and spaced on approximately 5.938" centers.

Submittal / Tech Data

6Z375

6" Stationary Louver

Frame: 6" deep, 6063-T5 extruded aluminum. .125" nominal wall thickness. Blades: 6063-T5 extruded aluminum. Blades are positioned at a 37.5° angle and spaced on approximately 5.938" centers.

Submittal / Tech Data

APD6

High Performance 6" Fixed Louver

Frame: .125" Extruded Aluminum, 6.20" Deep. Blade: .081 Extruded Aluminum positioned on a 37° angle on approximately 4.64" centers.

Submittal / Tech Data

APHFA6

High Performance 6" Fixed Louver

Frame: 0.125" Extruded Aluminum, 6.20" Deep. Blade: .081 Extruded Aluminum positioned on a 37° angle on approximately 4.64" centers.

Submittal / Tech Data
AMCA 540/550 Rated

D-HV-6

High Performance 6" Fixed Louver with Snow Resistance

Frame: .125" Extruded Aluminum, 6.26" (159 mm) Deep. Blades: .081 Extruded Aluminum on approximately 1.5" (37 mm) centers, horizontally and vertically.

Submittal / Tech Data
Miami Dade County Approved

DCFL-D-6

Dade County Florida Approved High Performance 6" Hurricane Lover

The Model DCFL-D-6 is a louver designed to protect the outside opening in building exterior walls. It is engineered for use in Dade County and its municipalities as well as other regions that use Dade County codes.

Submittal / Tech Data

7 Inch Louvers

Wind Driven Rain

7WDRL-V

7" Stationary Wind Driven Rain Resistant Louver

Frame: 7" deep, 6063-T5 extruded aluminum. .081" nominal wall thickness. Blades: 6063-T5 extruded aluminum. .068" nominal wall thickness. Double Drainable , sight-proof blades spaced on approximately 3.75" centers.

Submittal / Tech Data
Wind Driven Rain

7WDRL

7" Stationary Wind Driven Rain Resistant Louver

Frame: 7" deep, 6063-T5 extruded aluminum. .081" nominal wall thickness. Blades: 6063-T5 extruded aluminum. .068" nominal wall thickness. Double Drainable , sight-proof blades spaced on approximately 3.75" centers.

Submittal / Tech Data

APXSD7

High Performance Fixed Lover

Frame: .081 Extruded Aluminum, 7" (178 mm) Deep. Blades: .081" (2 mm) Extruded Aluminum on approximately 2.188" (56 mm) centers.

Submittal / Tech Data

9 Inch Louvers

AMCA 540/550 Rated

D-HV-9

High Performance 9" Fixed Louver with Snow Resistance

Frame: .081" Extruded Aluminum, 4.16" Deep. Blades: .081 Extruded Aluminum on approximately 4.625" centers

Submittal / Tech Data

Miscellaneous Louver Information

Typical Installation Details

Contact Air Performance for any additional information on special requirements.

Installation Details

Screen Details

Cloth, Mesh, Insect, Expanded Metal

1/2 Inch to 3/4 Inch Galvanized to Expanded Metal screens.

Submittal / Tech Data

Standard Formed Sill Extension

1" x 3" x 1" Sill Extension

.040, .050, .063, .080, 125 Thickness options on a 1" x 3" Sill Extension

Submittal / Tech Data

Architectural Special Shape Louvers

Standard and non-standard blade widths.

Customized to your specific needs and dimensions with standard and custom blade widths. Contact us for more information.

Submittal / Tech Data

BV4

Brick / Block Vent

FRAME 4" deep, 6063-T5 extruded aluminum. .125" minimum frame thickness BLADES 6063-T5 extruded aluminum. .125" thick 6063-T5 extruded aluminum 1" deep overlapping blade at 45 deg angle Blades spaced on 1" centers

Submittal / Tech Data

BV4-OBD

Brick/Block Vent with Opposed Blade Damper

FRAME 4" deep, 6063-T5 extruded aluminum. .125" minimum frame thickness BLADES 6063-T5 extruded aluminum. .125" thick 6063-T5 extruded aluminum 1" deep overlapping blade at 45 deg angle Blades spaced on 1" centers

Submittal / Tech Data

BV15FL

Brick/Block Vent W/1" Face Flange

FRAME 1 1/2" deep, 6063-T5 extruded aluminum. .125" minimum frame thickness 1" Face Flange BLADES 6063-T5 extruded aluminum. .125" thick 6063-T5 extruded aluminum 1" deep overlapping blade at 45 deg angle Blades spaced on 1" centers

Submittal / Tech Data

BV15FL-KFD

Brick/Block Vent W/1" Face Flange & Exterior Key Flap Damper

FRAME 1 1/2" deep, 6063-T5 extruded aluminum. .125" minimum frame thickness 1" Face Flange BLADES 6063-T5 extruded aluminum. .125" thick 6063-T5 extruded aluminum 1" deep overlapping blade at 45 deg angle Blades spaced on 1" centers

Submittal / Tech Data

BV15FL-OBD

Brick/Block Vent W/1" Face Flange & Opposed Blade Damper

FRAME 1 1/2" deep, 6063-T5 extruded aluminum. .125" minimum frame thickness 1" Face Flange BLADES 6063-T5 extruded aluminum. .125" thick 6063-T5 extruded aluminum 1" deep overlapping blade at 45 deg angle Blades spaced on 1" centers

Submittal / Tech Data

BVC

Cast Aluminum Brick/Block Vent

STANDARD CONSTRUCTION One piece molded unit Minimun .125" thick Mill finish Continuous weepage at bottom 1" deep overlapping blades Water stop at rear Load bearing

Submittal / Tech Data

BVC-KFD

Cast Aluminum Brick/Block Vent with Exterior Key Flap Damper

STANDARD CONSTRUCTION One piece molded unit Minimun .125" thick Mill finish Continuous weepage at bottom 1" deep overlapping blades Water stop at rear Load bearing

Submittal / Tech Data

ECS

Perimeter Frame: 0.125" (3.18 mm) to 0.25" (6.35 mm) Extruded Aluminum. Linear Bar Grills: 0.125" (3.18 mm) to 0.25" (6.35 mm) Extruded Aluminum.

Submittal / Tech Data

Perforated Face Panel Option

Perforated metal options available in various material thicknesses, hole sizes and configurations. This unique accessory allows for an aesthetically pleasing option as desired. Available with multiple louver models.

Submittal / Tech Data CAD

Please complete this form to send your project specifications or information and a sketch or drawing (if possible) or email to [email protected] for additional information.

Your Name